在tia门户v14 sp1上,我在profinet上有s7300和丹佛斯fcd302。
on tia portal v14 sp1, i have s7300 and danfoss fcd302 on profinet.
按照丹佛斯手册进行配置后,profinet通信不起作用。
After configuration as from danfoss manual, the profinet communication doesn't work.
PLC将驱动器名称分配给相对IP和正确的PPO,但我看不到I/O地址。
PLC assign drive name to the relative IP and the correct PPO, but I cannot see the I/O address.
CPU中没有警告或警报,逆变器上的参数正常。
No warning or alarm in the CPU, parameters on the inverter are ok.
与S71500相同的配置效果良好。
The same configuration with a S71500 works fine.
有人使用过FCD302吗?
Anyone have experience with FCD302?
谢谢
Thanks
封闭原因问题发布了两次。
closed cause question posted twice.
主题的第二条线索profinet通信s7300<->丹佛斯fcd在同一会议内发布通信/网络
The second thread with the subject profinet comm. s7300 <-> danfoss fcd is published within the same conference Communication / Networks
问候
CS主持人
Best regards
CS Moderator
...第三方硬盘,您提供的信息很少:您控制的是哪种型号的丹佛斯硬盘,您使用的是哪一种型号的安川硬盘。每个都使用什么Profibus接口? You give very little information on the 3rd-party drives you are replacing in your project: what model Danfoss drive did...
...,可以在硬件配置中添加DP NORM,并手动设置IO大小是否有Profinet同等产品谢谢 In a profibus system, when one does not have a GSD file for a third party peice of equipment, one would add a DP NORM to thehardware configand manually set the IO sizes.Is there a Profinet equivelan...
...述你好,专家们 hello, experts如何配置s7319t和im153-4之间的profinet irt通信? how to configurate the profinet irt communication between s7 319t and im153-4?请给我看看详细信息。 pls show me the detail information .提前谢谢你。 thank you in advance.推荐答案2S7-319T...
问题描述尊敬的各位:, Dear All,是否可以通信任何第三方设备/驱动器以连接Profibus上的S7300R系统? Is it possible to Communicate any thrid Party devices/Drives to connnect with S7300R System on Profibus?我已经阅读了以下文章,但我仍然需要理由。 i ha...
...Dear All,在我的一个项目中,我需要通过Profibus DP与S7400H PLC通信。 In one of my Project, i need to Communicate S7300 PLC with S7400H PLC via Profibus DP.请告诉我怎么做?? Please let me know how it can be done??推荐答案2你好,阿米特; Hello Amit;在西门子的...
问题描述我有一份工作,我将使用一些FC51型丹佛斯变频器。 I have a job where I shall used some Danfoss frekvent converter type FC51.我已经做了一个测试,MB_Master上没有错误,唯一的事情是我每次做REQ时都可以看到Busy开/关。 I have made a test and ...
...离中央PLC cpu所在位置约1公里的地方。I/O模块和PLC之间的通信将通过无线无线链路实现。 The task is to locate input / output modules about 1 KM away from where the central PLC cpu is located. Communication between the I/O modules and the PLC is to be effected via a wirel...
...通过isoTCP协议在CPU312(S7300)和CPU1211(S71200)之间建立了通信。 i have established a communication between CPU312 (S7300) and CPU1211 (S71200) over isoTCP protocol.在S7300侧i;m使用AGSEND和AGRCV块。 On S7300 side i;m using AGSEND and AGRCV blocks.我的问题是在S71200...
...已经通过isoTCP在CPU312(s7300)和CPU1211(s71200)之间建立了通信。 i have established a communication between CPU312 (s7300) and CPU1211 (s71200) over isoTCP.我的问题是在s71200一侧,在那里我使用TSEND&TRCV块。 My question is on s71200 side, where i'm using TSEND...
问题描述大家好, Hello All,在PCS7项目中,我必须将丹佛斯FC 202驱动器与MCA 101 profibus DP卡连接起来。 I have to connect Danfoss FC 202 drive with MCA 101 profibus DP card in the PCS7 project.我正在处理PCS7 V8.1。 I am working on PCS7 V8.1.我已成功为上述卡...
如果觉得我的文章对您有用,请随意打赏。你的支持将鼓励我继续创作!