我想知道是否有论坛成员有使用Anybus串行服务器产品的经验,通过我们的工厂生产网络创建从PLC到编程设备的连接。
I am wondering if any forum members have experience with this Anybus Serial Server product, creating a connection from the PLCto the programming device via our plant procuction network.
具体来说,我需要在我们的Sinumerik NCU中创建与集成PLC的网络链接,严格用于在线第7步编程/监控。我已经向Simatic和Sinumerik支持人员询问了西门子解决方案(即通信处理器),但给人的印象是解决方案并不存在,这让我想到了Anybus转换器。
Specifically, I am in need of creating the network link to the integrated PLC in our Sinumerik NCU's strictly for online Step 7 programming/monitoring. I have inquired with bothSimatic and Sinumeriksupport staff as to a Siemens solution (ie communications processor) but have been given the impression that the solution does not exist, which brings me to the Anybus converter.
根据Anybus串行服务器,它需要一个MPI加密狗,在Anybus模块和PLC编程端口之间的两端各有9针Dsub连接器。
As per the Anybus Serial Server, it requires an MPI dongle, with 9 pin Dsub connectors on each end, between the Anybus module and the PLC programming port.
串行服务器软件还在用户PG上创建与目标设备的IP地址相关的虚拟COM端口。这些虚拟COM端口创建后会显示在PG/PC接口设置实用程序的接口选择中吗?
The Serial Server software also creates virtual COM ports on the user PG which relate to the IP address of the target device. Do these virtual COM ports show up in the interface selction of the PG/PC interface setup utility once they have been created?
如有任何信息或示例,我们将不胜感激,
Any info or examples would be greatly appreciated,
谢谢
Thanks.
你好
Hello,
PG/PC接口面板不支持COM端口。
COM Ports are not supported by PG/PC Interface panel.
查看名为NDIS WAN IP的条目,然后尝试链接。
Have a look about an entry named NDIS WAN IP maybe and try to link.
如果未显示,则Anybus串行服务器、操作系统和步骤7的组合可能无法工作。
If this is not shown, then maybe the combination of Anybus Serial Server, your operating System and Step 7 doesn't work.
我只发现以下内容“申请说明“从Anybus连接到PROFIBUS/MPI(与RS485不同)
I found only following"Application note" from Anybus for connecting to PROFIBUS / MPI (which is not the same as RS485)
...ig编辑器重写,减少26个字节。这是因为HWConfig编辑器设计用于压缩所有Profibus从设备的I/O范围(如果可以的话)。您必须在Profibus配置中进行纠正,或调整程序以读取这些新地址。所以,如果没有问题,就让一切保持原样。 Modifyi...
...MPI、PROFIBUS和PPI the S7 IBHLink supports MPI, PROFIBUS, and PPI通过以太网,您可以获得机器的所有数据,以便通过标准OPC协议将其加载到IFIX SCADA中 Throught the Ethernet you can get all your datas for the machinery to load it in your IFIX SCADA via the standard OPC pr...
...我的PC,我可以用simatic管理器连接到两个PLC。但当我通过以太网连接时,我只能连接到1个PLC(带有CP343-1的PLC) If I connect my PC local on the MPI network, i can connect to both PLC's with the simatic manager. But when i connect through Ethernet i can only connect...
问题描述我想在pc en cpu 315-2dp 2af03之间对Simatic net Opc服务器进行测试。为此,我必须设置plc的硬件,以便在Netpro中插入S7连接,无论是未指定的连接还是与Opc服务器的连接(如果在同一项目中)我想通过profibus的mpi运行通信,因此...
问题描述你好 Hi,我必须通过以太网TCP/IP与CPU412-5H通信CPU1215C。 I have to communicate CPU1215C with CPU412-5H over ethernet TCP/IP is it possible.我不清楚Profinet端口是否可以用作以太网端口。 I am not clear wherher Profinet ports can be used as ethernet ports.请...
... You do not need the subnet id.您只需要关联的PLC地址(MPI、DP、以太网IP) You just need the associated PLC Adress (MPI, DP, Ethernet IP)推荐答案4谢谢穆洛夫 Thankyou Murof在视频中,它显示我需要PLC备份来配置。但我没有PLC备份,因为它有密码保护...
...llo,您是否也尝试过在Simatic Manager中使用目标系统->编辑以太网节点这里有显示的内容吗谨致问候 have you also try Target System -> Edit Ethernet Nodes in Simatic Manager?Is here something displayed?Regards克里斯托夫 Christoph推荐答案15是的,我尝试...
...CPU 314和MPI总线的机器。有没有便宜的解决方案将它们与以太网连接? there are three machine with CPU 314 and MPI buses Occupied By HMI are there any cheep solution to connect them with Ethernet ?我有TIA Portal V14 Upd1 I have TIA Portal V14 Upd1 推荐答案2你...
问题描述我需要13个串行端口(CM PtP RS422/485 BA)连接到CPU 1513-1个。是否有好处或以下选项的缺点? I need 13 serial ports (CM PtP RS422/485 BA) connected to a CPU 1513-1 PN. Are there benefits or disadvantages with the following options?将所有13个CM PtP模块与...
...协议可靠,但现在对您来说也“有点”复杂。问题是,主服务器需要通过每个CP向从服务器发送什么数据,以及它需要多少字节,比如说我们需要一个CP。如果您愿意回答这个问题,那么通过ASCII解决可能会更容易、更快。 in my op...