我们有一个S7 414-5H冗余系统,具有冗余Profibus架构
现在,我们的客户希望在PLC/DCS和他们的DCS(同样是西门子S7 400H)之间使用DP耦合器进行一些数据交换。他们还需要冗长的沟通。如何在冗余模式下安装和配置Profibus DP耦合器
提前感谢大家的回答
--
问候,
Dear All,
We have one S7 414-5H redundant system with redundant Profibus architecture.
Now our customer wants to have some data exchange between our PLC/DCS and their DCS (again Siemens S7 400H), using DP coupler. They wantredundant communication also. How can i install and configure Profibus DP couplers in redundant mode?
Thank all in advance for your great answers.
--
regards,
Baker
亲爱的各位,
Dear all,
请帮我找到解决办法。
Please help me to findout a solution.
提前感谢您的回复。
Thanks in advance for all your replies.
--
--
当做
regards,
Baker Ajmal公司
Baker Ajmal
你看到这些了吗?
Have you seen these?
类似主题:
Similar topic:
关于如何在DP托盘上设置冗余DP的主题:
Topic about how to set up redundant DP on a DP salve:
DPDP耦合器手册
DPDP coupler manual
http://support.automation.siemens.com/WW/view/en/1179382
http://support.automation.siemens.com/WW/view/en/1179382
祝你好运
Good luck!
...趣的部分。。。 Now here is the fun part...-我现在将ET200M插入PROFIBUS冗余。 -I will now insert my ET200M in PROFIBUS REDUNDANCY.-IM(1)连接在PROFIBUS DP 1中,IM(2)连接在PROFIBUS DP 2中。(根据目录) -IM(1) is connected in PROFIBUS DP 1 and IM(2) in connected...
...face to a redundant H system.Y链路由两个IM 153-2接口模块和一个Y耦合器组成。 The Y link consists of two IM 153-2 interface modules and a Y coupler.Y链路通过接口模块连接到冗余DP主系统。远程IO设备通过Y耦合器连接到Y链路,即: The Y link is connected...
...。不幸的是,现有目录中没有提供所有必需的模块(Im和Y耦合器)。你能帮我更新一下硬件目录吗?如果我更新了目录,现有的目录不会受到影响吗?更新目录只能在我的EWS中完成,不能在CPU中下载? Im trying to do hardware configurat...
... the attachment, explained in the following manual:SIMATIC总线链接DP/PA耦合器、有源磁场分配器、DP/PA链路和Y链路 SIMATIC Bus links DP/PA coupler, active field distributors, DP/PA Link and Y Linkhttps://support.industry.siemens.com/cs/ww/en/view/1142696 https://support.industry.si...
问题描述大家好, Hi All,S7-400机架是否有profibus耦合器? Is there any profibus coupler for S7-400 racks?顺致敬意, Best regards阿扎德 Azad推荐答案2你好,阿扎德; Hello Azad;S7-400机架没有Profibus从机IM,例如S7-300/ET 200M(IM 153-2)或ET 200S(IM 151-...
...止模式或关闭时,第二个PLC不会进入运行模式。连接到Y耦合器的从属设备在诊断缓冲器中没有任何问题,但我确实对连接到PLC 1的其他Profibus设备的地址有问题。因此,在诊断缓冲区警报中显示了硬件配置图中所示的PLC 2网络A和D...
...53-2(153-2BA02-0XB0)和EM277 Profibus DP(6AG1277-0AA22-2XA0)的Y型耦合器(153-2BA 02-0XB)。概述请参见附图。 We have two CPUs in our plant. i.e. CPU 417-4H (6ES7 417-4HL04-0AB0) and s7-200 ( 6AG1214-1BD23-2XB0). Y-coupler (153-2BA02-0XB0) with two IM153-2 (153-2BA02-0XB0) a...
...有发现QW178? In hardware configuration, you find no QW178?也许DP/DP耦合器使用它? Perhaps the DP/DP couplers use it?顺致敬意, Best regards,向导 Wizard推荐答案10你好 Hi,没有在HW配置或参考编辑器QW178中使用也检查了DP耦合器 no either in HW config or refer...
...时,我的同事联系了西门子,得知问题可能是配置的PN/PN耦合器版本(v2.0)和物理连接的版本(v3.0)之间存在差异。 In the meantime my colleague contacted Siemens, was advised that possibly the problem is in discrepancy between version of PN/PN coupler configu...
...00M,这不是问题。然而,我还必须连接一条额外的非冗余Profibus DP总线。在目前的概念中,我被告知使用每个CPU上的一个DP接口连接ET200Ms,CPU的其他两个DP接口则连接到中继器的一侧,形成一个段,并连接到中发器另一侧的非冗...